MKD-D1 Series Flameproof Armoured Cable

? Outdoor or indoor use.
? For use with single wire armour ‘W’, wire braid ‘X’ and steel tape armour ‘Z’ elastomer and plastic insulated cables.
? For particular use with:-
a) Cable inner sheaths that are not effectively filled, compact and/or circular, have tape bedding or have hygroscopic fillers.
b) Cables that exhibit ‘cold flow’ characteristics.
c) Enclosures containing an ignition source in gas group IIC areas or containing an ignition source in a Zone 1 area.
? Provides a barrier seal between the individual insulated cores within the cable and prevents entry of the products of an explosion into the cable.
? Provides armour clamping, using one clamping arrangementfor all armour/braid types.
? Provides an outer deluge seal to prevent moisture ingress to the cable armour/braid.
? Provides a cable retention and low smoke and fume, zero halogen seal onto the cables outer sheath.

download

Service hotline:
0523-88317000 88318288

Parameter
  • Technical Data

    ? Suitable for use in Zone 1, Zone 2, Zone 21, Zone 22 and in Gas Groups IIA, IIB and IIC.
    ? Construction and Test Standards: IEC/EN 60079-0, IEC/EN 60079-1, IEC/EN 60079-7 and IEC/EN 60079-31.
    ? Ingress Protection: IP66, IP67 and IP 68* (30 metres for 7 days) to IEC/EN 60529 and NEMA 4X.
    ? Operating Temperature Range: -60°C to +140°C.
    ? Deluge Protection to DTS01.
    ? Material: brass, nickel plated brass or stainless steel 304、316L
    ? Ex-marking: II 2 GD
    Ex d IIC Gb Ex e IIC Gb Ex tb IIIC Db IP68